This guide provides a complete introduction to visual reinforcement audiometry (VRA) testing. Table of contents What is visual reinforcement audiometry (VRA)? VRA transducers Stimuli selection Prepar…
Type: Reading
Table of contents What is speech audiometry? Why perform speech audiometry? Contraindications and considerations Audiometers that can perform speech audiometry How to perform speech audiometry? Resul…
Type: Reading
What is the hearing aid transition (HAT) test? We understand you have new patients who attend with their existing hearing aid and sound preferences, but you do not have their historic fitting session…
Type: Reading
Jack Bennett, International Clinical Trainer at the Interacoustics Academy, describes how to perform Unaided Real Ear Measurements. This includes how to check for contra indications during otoscopy…
Type: Video
What is the Hughson-Westlake procedure? The Hughson-Westlake procedure is an automatic pure tone audiometry test. In this test method, the threshold of hearing is defined as 2 out of 3 (or 3 out of 5…
Type: Reading
What is the Hughson-Westlake procedure? Hughson Westlake is an automatic pure tone test procedure. In this test method, the threshold of hearing is defined as 2 out of 3 (or 3 out of 5) correct respo…
Type: Reading
What is the Hughson-Westlake procedure? The Hughson-Westlake procedure is an automatic pure tone audiometry test. In this test method, the threshold of hearing is defined as 2 out of 3 (or 3 out of 5…
Type: Reading
What is the Hughson-Westlake procedure? The Hughson-Westlake procedure is an automated pure tone audiometry test. During the ascending portion of the tone presentation, the threshold of hearing is de…
Type: Reading
Summary of: Don, M., & Elberling, C. (1994). Evaluating residual background noise in human auditory brain-stem responses. The Journal of the Acoustical Society of America, 96(5 Pt 1), 2746–2757. http…
Type: Reading
The calibration procedure for lateral canal calibrations has not changed and is described in the manual. You can begin testing without calibrating by selecting a test and starting the impulses. In th…
Type: Reading
What is Békésy audiometry? Békésy audiometry is an automatic method of measuring audiometric thresholds. It can be used for audiometric screening or in differentiation between the cause of the hearin…
Type: Reading
What is Békésy audiometry? Békésy audiometry is an automatic method of measuring audiometric thresholds. It can be used for audiometric screening or in differentiation between the cause of the hearin…