Search

Search Results for '8'
Yes VEMPs can be used in a number of ways and, like a number of vestibular diagnostic tests associated with Meniere’s disease, the result and the interpretation depend to a large extent of the point…
Type: Reading
Yes VEMPs can be used in a number of ways and, like a number of vestibular diagnostic tests associated with Meniere’s disease, the result and the interpretation depend to a large extent of the point…
Type: Reading
Yes VEMPs can be used in a number of ways and, like a number of vestibular diagnostic tests associated with Meniere’s disease, the result and the interpretation depend to a large extent of the point…
Type: Reading
Summary of: Hof, J. R., de Kleine, E., Avan, P., Anteunis, L. J., Koopmans, P. J., & van Dijk, P. (2012). Compensating for deviant middle ear pressure in otoacoustic emission measurements, data, and…
Type: Reading
Summary of: Stinson, M. R., Shaw, E. A., & Lawton, B. W. (1982). Estimation of acoustical energy reflectance at the eardrum from measurements of pressure distribution in the human ear canal. The Jour…
Type: Reading
Summary of: Voss, S. E., Merchant, G. R., & Horton, N. J. (2012). Effects of middle-ear disorders on power reflectance measured in cadaveric ear canals. Ear and hearing, 33(2), 195–208. https://doi.o…
Type: Reading
Summary of: Cebulla, M., & Elberling, C. (2010). Auditory brain stem responses evoked by different chirps based on different delay models. Journal of the American Academy of Audiology, 21(7), 452–460…
Type: Reading
Air-bone gaps are the difference in sensitivity threshold between air and bone conduction transducers. This measurement helps distinguish between conductive and sensorineural hearing losses, as well…
Type: Reading
I’ve noticed a consistent air bone gap at 4000 Hz during audiometry. Can you explain why this happens? For a complete answer to this issue the reader is strongly urged to read Margolis et al. (2013)…
Type: Reading
Table of contents What are real-ear measurements? Why perform real-ear measurements? Contraindications to performing real-ear measurements How to perform real-ear measurements Important steps after t…
Type: Reading
In this article, we will equip you with everything you need to know to feel confident selecting and fitting a CROS or a BiCROS hearing aid. Table of contents What is CROS? What is BiCROS? Factors to…
Type: Reading
The real-ear-to-coupler difference (RECD) is the difference between the coupler response and the real ear response. This guide will provide an introduction to RECD testing. Table of contents Why does…
Type: Reading

Interacoustics - hearing and balance diagnosis and rehabilitation
Copyright © Interacoustics A/S. All rights reserved.