Search

Search Results for 'real ear verification for hearing aids'
The aided cortical test can be likened to an evoked potentials method for performing a speech test. This guide will provide a complete introduction to aided cortical testing. Table of contents What i…
Type: Reading
In this article, we will equip you with everything you need to know to feel confident selecting and fitting a CROS or a BiCROS hearing aid. Table of contents What is CROS? What is BiCROS? Factors to…
Type: Reading
The real-ear-to-coupler difference (RECD) is the difference between the coupler response and the real ear response. This guide will provide an introduction to RECD testing. Table of contents Why does…
Type: Reading
Table of contents What are real-ear measurements? Why perform real-ear measurements? Contraindications to performing real-ear measurements How to perform real-ear measurements Important steps after t…
Type: Reading
Jack Bennett, International Clinical Trainer at the Interacoustics Academy, describes how to perform Real Ear Aided Response (REAR) measurements and how to interpret and adjust the hearing aid freque…
Type: Video
Jack Bennett, International Clinical Trainer at the Interacoustics Academy, introduces Real Ear Measurements and the steps needed to perform them. He also discusses why they are so important in Heari…
Type: Video
What is the real ear to coupler difference (RECD)? The Real Ear to Coupler Difference (RECD) is a measurement that accounts for the decibel difference across frequencies between SPL measured in the c…
Type: Reading
What is the real ear to coupler difference (RECD)? The real ear to coupler difference (RECD) is a measurement that accounts for the decibel difference across frequencies between SPL measured in the c…
Type: Reading
What is the real ear to coupler difference (RECD)? The real ear to coupler difference (RECD) is a measurement that accounts for the decibel difference across frequencies between SPL measured in the c…
Type: Reading
The BSA Clinical Practice Guidelines recommend using the NAL-NL1/NAL-NL2 fitting formulae when performing Adult hearing aid verification. The choice between the use of the REIG (insertion gain) or th…
Type: Reading
The BSA Clinical Practice Guidelines recommend using the NAL-NL1/NAL-NL2 fitting formulae when performing Adult hearing aid verification. The choice between the use of the REIG (insertion gain) or th…
Type: Reading
The BSA Clinical Practice Guidelines recommend using the NAL-NL1/NAL-NL2 fitting formulae when performing Adult hearing aid verification. The choice between the use of the REIG (insertion gain) or th…
Type: Reading

Interacoustics - hearing and balance diagnosis and rehabilitation
Copyright © Interacoustics A/S. All rights reserved.