What is Békésy audiometry? Békésy audiometry is an automatic method of measuring audiometric thresholds. It can be used for audiometric screening or in differentiation between the cause of the hearin…
Type: Reading
What is the Hughson-Westlake procedure? The Hughson-Westlake procedure is an automatic pure tone audiometry test. In this test method, the threshold of hearing is defined as 2 out of 3 (or 3 out of 5…
Type: Reading
What is Békésy audiometry? Békésy audiometry is an automatic method of measuring audiometric thresholds. It can be used for audiometric screening or in differentiation between the cause of the hearin…
Type: Reading
What is the Hughson-Westlake procedure? The Hughson-Westlake procedure is an automated pure tone audiometry test. During the ascending portion of the tone presentation, the threshold of hearing is de…
Type: Reading
What is the tone decay test? The tone decay test can help to identify the adaptation of the auditory system (Carhart, 1957). It involves measuring the perceptual reduction in a continuous tone over t…
Type: Reading
What is the tone decay test? The tone decay test helps to identify the adaptation of the auditory system (Carhart, 1957). It involves measuring the perceptual reduction in a continuous tone over time…
Type: Reading
What is pure tone audiometry? Pure tone audiometry is a hearing test that establishes the hearing sensitivity at various frequencies for air conduction and bone conduction. The test can specify the a…
Type: Reading
What is the Hughson-Westlake procedure? Hughson Westlake is an automatic pure tone test procedure. In this test method, the threshold of hearing is defined as 2 out of 3 (or 3 out of 5) correct respo…
Type: Reading
What is the Hughson-Westlake procedure? The Hughson-Westlake procedure is an automatic pure tone audiometry test. In this test method, the threshold of hearing is defined as 2 out of 3 (or 3 out of 5…
Type: Reading
It's easy and only takes approximately 2 minutes to perform the Audible Contrast Threshold (ACT) test on Affinity Compact. Learn how to instruct your patient, how to do the actual test and how to use…
Type: Video
Ce guide fournit aux cliniciens une introduction complète à la réalisation et à l’interprétation du test calorique. Table des matières Qu'est-ce que le test calorique ? Physiologie du test calorique…
Type: Reading
The OtoRead™ Micro-Probe The OtoRead™ micro-probe utilizes a disposable probe tube (probe tip) design. Removal and replacement of the probe tube is fast and easy, saving the clinician time spent on c…
Type: Reading