Probe, Short Extension Cable, Preamplifier Clinical Extension Cable 1. Unscrew the probe cap. 1. Unscrew the probe cap. 2. Remove the probe tip. 2. Remove the probe tip. 3. Thread the stiff end of th…
Type: Reading
Probe/Short extension/Preamplifier Step 1: Unscrew the probe cap. Step 2: Remove the probe tip. Step 3: Replace with a clean probe tip. Step 4: Assemble the probe again (step 2+1). Clinical extension…
Type: Reading
About the author The information presented here is based on clinical examples as well as modeled patterns. Text and accompanying absorbance sketch is authored by Navid Shahnaz, PhD, Aud, Associate Pr…
Type: Reading
About the author The information presented here is based on clinical examples as well as modeled patterns. Text and accompanying. Absorbance sketch is authored by Navid Shahnaz, PhD, Aud, Associate P…
Type: Reading
About the author The information presented here is based on clinical examples as well as modeled patterns. Text and accompanying. Absorbance sketch is authored by Navid Shahnaz, PhD, Aud, Associate P…
Type: Reading
Prepare the equipment Turn on Titan by pressing the R or L button. Choose the test protocol from the list using the up & down arrow keys and then press Select. To use a different protocol than the on…
Type: Reading
It's easy and only takes approximately 2 minutes to perform the Audible Contrast Threshold (ACT) test on Affinity Compact. Learn how to instruct your patient, how to do the actual test and how to use…
Type: Video
Preparing the skin Always use an abrasive preparation gel (e.g., NuPrep) to ensure that the top layer of skin (epidermis) is cleaned and oil is removed. The skin may become a little red after an appr…
Type: Reading
Launch the Equinox Suite and ensure you are in the AUD module (click on the AUD tab on right hand side of the screen if not). Choose TEN Test from the Protocols and sessions drop-down menu. Select th…
Type: Reading
Test procedure Launch the Equinox Suite from Noah, OtoAccess®, or standalone. Click on the AUD tab on the upper right-hand side of the screen. Ensure that your audiometry has been performed ahead of…
Type: Reading
Required equipment Equinox Evo Bone oscillator A patient response button Headphones or insert phones Test procedure Launch the Equinox Suite as standalone, from Noah, or from OtoAccess®. Click on the…
Type: Reading
Test procedure Launch the Equinox Suite from Noah, OtoAccess® or standalone. Click on the AUD tab on the upper right-hand side of the screen. Perform audiometry before the ANL test as this determines…