Description: AC40, AD226, AD629 & NEW AT235 supports direct print-out to a range of standard PC USB printers with standard printer language HP PCL 5/HP PCL 3, e.g. HP and Canon printers. The instrume…
Interacoustics supplies calibration equipment from both Brüel & Kjær and G.R.A.S. Both manufacturers produce complete calibration sets with the exception that only Brüel & Kjær offers an artificial m…
What is the real ear to coupler difference (RECD)? The real ear to coupler difference (RECD) is a measurement that accounts for the decibel difference across frequencies between SPL measured in the c…
Type: Lectura
What is an electrical auditory brainstem response (eABR)? An electrical auditory brainstem response (eABR) is a measurement of the ABR using an electrical stimulus. Instead of a traditional acoustic…
Type: Lectura
What is the real ear to coupler difference (RECD)? The Real Ear to Coupler Difference (RECD) is a measurement that accounts for the decibel difference across frequencies between SPL measured in the c…
Type: Lectura
What is the real ear to coupler difference (RECD)? The real ear to coupler difference (RECD) is a measurement that accounts for the decibel difference across frequencies between SPL measured in the c…
Type: Lectura
This document serves as a quick run through on how to perform an aided cortical measurement. We refer to the Eclipse support page that contains the Additional Information and Instructions For Use doc…
Type: Lectura
Introduction: The safety of Medical devices is demonstrated by testing the device to requirements of the safety standard for medical devices (ref. 2). When the device is manufactured, each unit will…
Description: This bulletin is to clarify the selection of HDMI (High-Definition Multimedia Interface) monitors used with the AC40. We have received reports from the field that certain monitors with H…
AC40, AD629, AD226, NEW AT235 & NEW AA222 support direct print-out to a range of standard PC USB printers with standard printer language: HP PCL 5e, HP PCL 3, HP PCL3GUI Canon BJ(300/360 dpi), Canon…
Issue: Spectrum software cannot open and will give Error 3343: Unexpected Database Format for multiple MRC files (Patients.mrc, Reserved.mrc, Utility.mrc). Symptom/Summary: The Spectrum software will…
Description: EyeSeeCam vHIT camera design has been updated with ventilation fan from March 2017. The EyeSeeCam vHIT camera now has a built-in ventilation fan, which controls the surface temperature o…