The Gold standard for threshold assessment

Response amplitudes typically 50% larger than tone burst responses, with the potential to halve the test time.
The Challenge

Identifying wave V close to threshold

Correctly diagnosing the type and degree of hearing loss so that rehabilitation can occur, is one of the most important roles of an audiologist or physician.
Click and tone burst ABR have been successfully used for many years, but despite their common clinical use these stimuli are associated with long test times and small wave V amplitudes. This results in ABR traces which are diffcult to interpret and leading clinicians to have less confidence in what they see on screen.
Large ABR waveforms are dependent on synchronous neural firing. Unfortunately, click and tone burst stimuli are not designed to stimulate the cochlea optimally. As the cochlea is tonotopically organised, the different frequency components of the click and tone bursts reach their point of stimulation on the basilar membranes at different times. This leads to temporal smearing of the ABR result shown on screen.
The Solution

CE-Chirp® stimulus family

The solution is to design a stimulus which stimulates all the desired frequencies of the basilar membrane at the same time.
Following many years of extensive human studies by numerous researchers the studies determined the delay model that had the best match for the average human cochlea; the outcome being the innovative CE-Chirp®. For the clinician this means larger amplitude waveform responses allowing for easier threshold identification1.
In 2007, Interacoustics was the first company to introduce the revolutionary CE-Chirp® into a diagnostic evoked potentials platform leading to markedly reduced test time and easier interpretation for the clinician. Response amplitudes up to twice the size when compared with traditional clicks or tone bursts can be achieved with both the broadband CE-Chirp® and frequency specific narrow band CE-Chirps®. The CE-Chirp® LS stimulus family is an overall improvement to the original CE-Chirp® stimulus family.
Guy Lightfoot

„Our work has shown that narrowband CE-Chirps® offer frequency-specific testing in typically half the time taken by tone pips. Given that a sleeping baby is a ticking time bomb waiting to go off, that’s an advantage you can’t afford to pass up. It’s frustrating that not all ABR systems offer this stimulus.“

PhD 2013 Guy Lightfoot

Interacoustics Academy

Expand your knowledge with the latest advancements in diagnostic audiology and balance presented by our experts, endorsed by the leading professional bodies.

Explore

Extensive Documentation

Looking for help? Take a look at our support center to find extensive documentation. From tips on getting started to how to test guides.

Explore

Find ways to buy our products: Visit an Interacoustics sales office, call 45-6371-3555, or find a distributor.
Features and/or functions may not be available for all countries or all areas and product specifications are subject to change without prior notification.